Introduction to GENT fixed frequency air to water heating system Air to water heating system is a heat pump unit that uses the heat in the air as the heating source, absorbs the heat in the air to prepare hot water. Combined with the indoor terminals and the hot water produced by the unit, the indoor space heating can be achieved. The thermo pump heating system is divided into two types: fixed frequency unit and variable frequency unit. This category mainly introduces the fixed frequency type. What is a fixed frequency heat pump house heater? The main difference between fixed frequency heaters and variable frequency heaters lies in the frequency at which the compressor in the unit runs. The compressor in the fixed frequency heatpump furnace runs at a fixed frequency. When the indoor temperature reaches the set value, the unit is completely shut down, and the unit restarts after the temperature drops. The operation mode of the fixed frequency Air Source Heat Pump Heating unit is a continuous cycle of "start-stop". Unit advantages 1. Initial equipment investment can save 30~50% 2. Low maintenance cost (no risk of inverter module failure) 3. Suitable for areas with low electricity prices 4. Recommended for: intermittent heating scenarios (such as weekend villas), mild climate areas (areas with the lowest temperature in winter above -5℃) Unit disadvantages 1. The compressor starts and stops many times, which increases power consumption and affects the service life of the unit. 2. The room temperature drops significantly during the winter defrosting period. 3. The COP of this heat pump heater is lower than that of the variable frequency unit. Heat Pump House Heater,Heat Pump Heater,Heat pump Furnace,Thermo Pump Heating,Electric Heat Pump Water Heaters GUANGZHOU GENT NEW ENERGY TECHNOLOGY CO., LTD , https://www.gentgz.com
Â
Engine Model
Â
JTA2160-G1
SpeedÂ
rpm
1500
FrequencyÂ
Hz
50
Rating Output
Â
Â
Continuous OutputÂ
kW
684
BMEP for Continuous Output
bar
15.47
Fan Reduction
kW
5.5
Single Fan Reduction
kW
5.0
Fan Quantity
rpm
1460
Basic Performance Datasheet
Â
Â
Aspiration Type
Â
Turbocharger air-water aftercooler
Configuration
Â
V
No. of Cylinders
Â
8
DisplacementÂ
l
35.4
BoreÂ
mm
170
StrokeÂ
mm
195
Compression Ratio
Â
12:1
Number of Flywheel TeethÂ
Â
218
Flywheel House Size
Â
SAE00-18
Cooling System
Â
Â
Coolant Capacity for EngineÂ
l
70
Max. permissible Temperature of Cylinder Inlet
°C
80
Max. permissible Temperature of Cylinder Outlet
°C
90
Max. Coolant Warning Temperature Â
°C
93
Max. Coolant Shutdown Temperature Â
°C
97
Thermostat Open TemperatureÂ
°C
71
Radiator Cooling Flow Â
m³/min
900
Energy Balance
Â
Â
Heat dissipation (engine radiator)± 8 %
kW
351
Heat dissipation (CAC)± 8 %
kW
60
Heat dissipation (Exhaust cooled to 120°C)± 8 %
kW
346
Gas Consumption + 5 %
kW
1683
Electrical EfficiencyÂ
Â
38.03%
Mechanical EfficiencyÂ
Â
40.67%
Thermal Efficiency
Â
41.41%
Total Efficiency
Â
82.09%
Engine Output at genset prime output
kW
684
Fuel Consumption at 100% of genset prime output+ 5 %
Nm3/hr
168.30
Intake & Exhaust System(On Continuous Output)
Â
Â
Combustion Air ConsumptionÂ
m³/min
66.53
Max. Intake RestrictionÂ
mbar
5.0
Gas Inlet Pressure Value
mbar
20-200
Gas Inlet PressureÂ
Â
± 10 %
Cylinder Max. Exhaust Temperature (before turbo)
°C
630
Max. Exhaust Temperature (after turbo)
°C
460
Min. Exhaust Back Pressure
mbar
30.0
Max. Exhaust Back Pressure
mbar
50.0
Exhaust Gas Flow Â
m³/min
167.53
Exhaust Flange DiameterÂ
mm
1*250
Emissions NOx
mg/Nm3
< 500
Engine Dimension
Â
Â
LengthÂ
mm
2596
WidthÂ
mm
1459
HeightÂ
mm
1820
Engine Dry Weight w/o Cooling System
kg
3500
1. All engine parameters are in accordance with ISO3046, ISO8528.
2. All engine parameters are based on 25° C / 100kPa environment condition.
3. Application for Power Generation, Marine, Pump Driving, CHP power plant.
Applied gas:
Natural Gas, Biogas, City Sewage Gas, Landfill gas, Oil gas, farm biogas, Coal mine gas, etc
Acceptable fuel gas pressure: 5~12kPa
CH4 content: For natural gas≥ 85% CH4, content: For biogas≥ 40%
Gas heat value≥ 5500kcal/Nm3 (23MJ/Nm3 ). Genset output power will increase as the gas heat value increase, if use low heat value gas for fuel (Heat value<5500kcal/Nm3, it will lower the power efficiency.
Gas doesn't include free water or free materials (the size of impurities should be less than 5μ M. )
H2S content≤ 200mg/Nm³
NH3 content≤ 20mg/Nm³
Impurities content≤ 30mg/Nm³ ; Size≤ 5μ M
Water content≤ 40g/Nm³ , no free water.
Acceptable working conditions:
Ambient temperature: -10° C~+40° C
(antifreeze or preheater needed for below 0° C)
Relative humidity: <90%(20° C)
Altitude: ≤ 1000m
Normal working conditions:
Genset can run at rated power on the conditions:
Atmospheric Pressure: 100kPa, Ambient Temp: 20° C, Relative Humidity: 30%.
Standard scope of supply:
1, Gas Engine
2, AC Generator
3, Common Frame
4, Control Panel
5, Ignition System: Ignition Controller, Ignition Coils, Output harness, Pickup magnetic, Trigger disc, PolyMot high tension lead, Spark Plug
6, Detonation Controller System: DetCon20 control unit, Detonation sensor, Cable & knock sensor
7, Electronic Speed Controller System: Integrated Throttle body, Vari-Step stepper motor card, Harness VariFuel, Electronic speed controller - ECON-4, pickup magnetic
8, Gas Mixer System: VariFuel air/fuel ratio mixer, VF Flange, VariStep stepper motor card, Harness VariFuel, VariFuel2 flow body
9. Emission Control System: EmCon5 control unit, EmCon5 sensor harness, knock sensor
10, Valve: Gas Pressure Valve, Solenoid Valve, Cutoff Valve
11, Exhaust Bellows & Muffler
12, Radiator for optional
Warranty:
All equipment is guaranteed for a period of 1000 hours running or 18 months from the date when the generator set has been delivered from the factory.
Googol Generator Use 684kw 50Hz AC Three Phase Gas Engine
Model NO.: JTA2160G1
Cooling Way: Water Cooled, Air Cooled, CHP, Cchp
Power Range: 684kw
Gas Methane: Biogas CH4:60%, CO2:40%; Natural Gas
Certificates: ISO, CE, BV, GOST, SGS, etc
Warranty: 1 Year or 1200 Working Hours
After-Sales Service Provided: Engineers Available to Service Machinery Overseas
Gas Train: Ball Valve, Gas Filter, Gas Regulator, Gas Control
Nox Emission: 100% Load Below 500mg/Nm3
Trademark: Googol
Transport Package: Standard
Specification: ISO3046, ISO8528
Origin: China
HS Code: 8502120000
Googol Generator Use 684kW 50Hz AC Three Phase Gas Engine  Therefore, it can be said that the fixed frequency electric heat pump water heaters can meet the demand for indoor heating, and this unit also has its advantages and disadvantages. Users can comprehensively consider your personal needs and the advantages and disadvantages of the unit to determine whether this unit is really suitable for you. If it is suitable, you can take it into consideration.